27-634
27-634
Check item or cause
Solution
Do the communications settings in this
software and on the robot controller match?
The communications settings in this software and on the
robot controller must match.
The communications settings for this software are made
on the project edit screen. For details, see
.
For the robot controller side, change the
communications parameters with the optional teaching
box. For details, see
"Detailed explanations of
functions and operations"
in the robot controller user's
manual.
(6)
When Communication Server 2 is yellow (overall)
When Communication Server 2 is displayed in yellow, check the following.
Check item or cause
Solution
Is this software in the "Online" status?
This software initially starts in the "Offline" status. When
you put it into "Online" status, it communicates with the
robot controller.
For details, see
"8.18 Offline/Online/Simulation"
.
(7)
When Communication Server 2 is in light blue or blue (overall)
If Communications Server 2 is displayed light blue or blue, but communications are still not possible, check
the following.
Check item or cause
Solution
Is there a communications error in this
software?
Check the contents of the communications error and
close the communications error window.
Is a simulation underway?
(Note) Only the standard edition has the
simulation function.
End the simulation.
Is the screensaver running on the
computer?
Close the computer's screensaver.
Is the computer's hard disk is power save
mode?
Close computer hard disk power save mode setting.
(8)
Communication with the robot controller is cut off mid-way through.
If you cannot communicate with the robot controller, check the following.
Check item or cause
Solution
Is the screen saver set, hard disk power off
set, system standby set, or system
shut-down set?
If any of these functions are running, they may cause a
communications time-out, so do not use any of these
functions.
Is some other product running that uses
communication?
Or is any permanent resident software
running that uses communication?
A computer communication port cannot be opened for
two applications, so either close the other application or
change the port that this software uses.
Summary of Contents for 3F-14C-WINE
Page 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Page 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Page 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Page 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Page 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Page 624: ...24 624 24 624 Figure 24 4 Document output example ...