27-635
27-635
4. Communications (RS-232)
If you cannot communicate with the robot controller using RS-232, check the following.
Also, see
"Communication (general)"
.
Check item or cause
Solution
What color is Communication Server 2?
Return Communication Server 2 to icon
status and check the color displayed for the
line state.
Red
The problem may be that the robot controller
is not connected correctly. Check the items
in
"(1) When Communication Server 2 is
.
Green
The problem may be that the robot controller
and the computer have different
communications settings. Check the items in
"(2) When Communication Server 2 is
green (RS-232)"
.
Yellow
See
.
Light blue Check the items in
Communication Server 2 is light blue or
blue. (RS-232
.
Blue
(1)
When Communication Server 2 is red (RS-232)
If Communication Server 2 is displayed in red with communication with the robot controller set to RS-232,
check the following.
Check item or cause
Solution
Is Communication Server 2 set for the
correct communication port
(COM1-COM10)?
The default value for this software is COM1. On some
computers, COM1 is not allocated to RS-232, but to an
infrared port, modem, or the like. Also, when using
RS-232 over USB, the port used for RS-232 may be
other than COM1.
Use the Windows device manager or the like to check
the COM number allocated to RS-232 and change the
"Port" setting in the communication settings to that port.
Is some other product running that uses the
communication port?
Or is any permanent resident software
running that uses the communication port?
A computer communication port cannot be opened for
two applications, so either close the other application or
change the port that this software uses.
In the communications settings for this
software, is the communication method set
to TCP/IP or USB?
Change the communication method to RS-232.
(2)
When Communication Server 2 is green (RS-232)
If Communications Server 2 is displayed green with communications with the robot controller set to RS-232,
check the following.
Check item or cause
Solution
Do the communication settings in this
software and on the robot controller match?
In particular, check that the protocol settings
match.
The communication settings in this software and on the
robot controller must match.
The default protocol for this software is "Procedural", but
for CRn-500 series robot controllers, the default protocol
is "Non-Procedural"
Summary of Contents for 3F-14C-WINE
Page 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Page 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Page 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Page 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Page 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Page 624: ...24 624 24 624 Figure 24 4 Document output example ...