27-632
27-632
3. Communications (general)
(1)
What are the means for communication with the robot controller?
With a CR800/750/700 series robot controller, you can communicate via USB, Ethernet, and RS-232.
With a CRn-500 series robot controller, you can communicate via Ethernet and RS-232. However, when
using Ethernet with a CRn-500 series robot controller, the robot controller must have the optional Ethernet
card.
For details, see
"9.1 Robots Connected and Types of Communication"
.
(2)
Where are the communications settings made?
They are made on the project edit screen. For details, see
.
For the robot controller side, change the communications parameters with the optional teaching box. For
details, see
"Detailed explanations of functions and operations"
in the robot controller's user's manual.
[Caution] The communication settings must be made on both this software and the robot controller.
If you change the robot controller settings, you must change the settings in this software too.
(3)
I cannot communicate with the robot controller.
If you cannot communicate with the robot controller, check the following.
Also see
,
, and
.
Check item or cause
Solution
Is the connected robot controller selected
correctly?
Check if the correct project is selected with this software.
For details, see
"8.18 Offline/Online/Simulation"
.
Is the robot controller power supply On?
Switch On the robot controller's power supply and check
that the robot controller starts up normally.
Is Communication Server 2 running?
Communication Server 2 is started
automatically when this software is started.
Communication Server 2 is started as an
icon.
If you closed Communication Server 2 by mistake, close
this software, then restart it.
Are you connected to a robot controller
other than the CR800/750/700/500 series?
Check the robot controller model name in its user's
manual (or standard specifications or the like).
Are the robot controller's network settings
correct?
The robot controller's network settings are made by the
parameters. Check the robot controller's network
settings with the optional teaching box.
Are the communications settings on this
software correct?
Set the correct communications settings.
For details, see
.
Is some other MELFA product running?
For example is E/EN series computer
support software or P/P or P/P-2 running?
Close any MELFA product other than this software.
For details, see
"1.6 When Starting at the Same Time
.
Summary of Contents for 3F-14C-WINE
Page 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Page 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Page 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Page 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Page 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Page 624: ...24 624 24 624 Figure 24 4 Document output example ...