18-403
18-403
18.1.10.
Playing back data
Clicking
the following buttons
in the [Oscillograph] tab -> [Playing Back Data] group on the ribbon, data can be
played back along the time axis while the cursor is moved automatically.
Figure 18-14 Data Playback Buttons
Clicking the [Playback] button moves the cursor along the time axis.
Clicking the [Rewind] or [Fast Forward] button moves the cursor at [x1] or [x2] speed, respectively. You can select
the speed from [x1]/[x2]/[x10] by clicking the button again.
To stop playback midway, click the [Pause] button.
Figure 18-15 Data Playback States on Oscillograph
18.1.11.
Save Data
/
Log Setting
Clicking
the
[
Save Data]
(
)
button
in the [Oscillograph] tab -> [Data File] group on the ribbon, the data
acquired up to that point in time can be saved in CSV file format.
The newest data can be written out to a log file at a set time interval. Clicking the [
Log Setting
] (
) button in
the [Oscillograph] tab -> [Data File] group on the ribbon,
select the [Log the Measurement Data] check box in the
operation dialog of the displayed log file.
The time interval written in a log file is specified in the [Select the
Interval Log] drop-down list.
Figure 18-16 Log file operation
Rewind (x1)
Fast Forward (x10)
Summary of Contents for 3F-14C-WINE
Page 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Page 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Page 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Page 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Page 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Page 624: ...24 624 24 624 Figure 24 4 Document output example ...