DVP-15MC Series Motion Controller Operation Manual
11-306
11
1
11.6.5.6
DMC_SetStartPosition
FB/FC
Explanation
Applicable model
FB
DMC_SetStartPosition instruction sets the start positions of axes of G
code.
DVP15MC11T
DVP15MC11T-06
DMC_SetSta rt Position
Ax esGroup
Done
DMC_SetSta rt Position_ins tanc e
Ex ecut e
X_S tartPos
Busy
Error
ErrorI D
Y_St art Pos
Z_Sta rt Pos
A_S tartPos
B_St art Pos
C_StartP os
P_S tartPos
Q _StartPos
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation timing
AxesGroup
The number of the axes
group
USINT
1~8
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE.
Execute
The instruction is
executed when
Execute
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(
FALSE
)
-
X_StartPos
Specify the start
positionof X axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
Y_StartPos
Specify the start
positionof Y axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
Z_StartPos
Specify the start
positionof Z axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
A_StartPos
Specify the start
positionof A axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
B_StartPos
Specify the start
positionof B axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
C_StartPos
Specify the start
positionof C axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
P_StartPos
Specify the start
positionof P axis.
LREAL
Positive number, 0,
negative number
(
0
)
When
Execute
changes from
FALSE to TRUE.
Q_StartPos
Specify the start
positionof Q axis.
LREAL
Positive number, 0,
negative number
When
Execute
changes from
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...