Chapter 8 Logic Instructions
8-247
8_
8.14.3.5
RS485_RS
FB/FC
Explanation
Applicable model
FB
RS485_RS is used to configure RS485 free protocol communication
parameters for the motion controller.
DVP15MC11T
DVP15MC11T-06
RS485_R S
Execute
RS485_R S_instance
Abor t
CyclicRun
Send_Buffer_Address
Send_Length
Receive_Buffer _Address
Receive_Length
Add_ST X_E TX
ET X1
ET X2
ST X
Timeout
Done
Busy
Aborted
NewCycle
Received
Receive_TimeOut
Receive_LengthOverM AX
Receive_ActulLength
Err or
Err or ID
Active
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation timing
Execute
The instruction is
executed when
Execute
changes from
FALSE to TRUE.
BOOL
TRUE or FALSE
(
FALSE
)
Abort
The free protocol
communication is
aborted when
Abort
changes to TRUE.
BOOL
TRUE or FALSE
(
FALSE
)
When
Execute
changes from FALSE
to TRUE
CyclicRun
Communication mode
setting for the
instruction.
FALSE: Non-cyclic;
TRUE: Cyclic
BOOL
TRUE or FALSE
(
FALSE
)
When
Execute
changes from FALSE
to TRUE
Send_Buffer_Address
Specify the starting
register of the master
where the sent data
are stored.
USINT
%MB0-%MB32767
When
Execute
changes from FALSE
to TRUE
Send_length
Set the length of sent
data.
UINT
0-200
(
Byte
)
(0)
When
Execute
changes from FALSE
to TRUE
Receive_Buffer_Address
Specify the starting
register of the master
where the received
data are stored.
USINT
%MB0-%MB32767
When
Execute
changes from FALSE
to TRUE
Receive_Length
Set the length of
received data.
UINT
0-200(Byte)
(0)
When
Execute
changes from FALSE
to TRUE
Add_STX_ETX
Set if the start and end
codes are added or not
in sent messages.
FALSE: Not add the
start and end codes.
TRUE: Add the start
and end codes.
BOOL
TRUE or FALSE
(
FALSE
)
When
Execute
changes from FALSE
to TRUE
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...