DVP-15MC Series Motion Controller Operation Manual
12-22
12
1
System error code
Explanation
Correction
Hexadecimal
Decimal
3026
12326
Watchdog timeout
Check if the program is correct or there is a
loop of which the program execution can not
get out when the program execution timeout
occurs.
3027
12327
Calling the axis state machine
failed.
Contact local technicians if the error still exists
after redownloading the program and restoring
to the factory setting.
3028
12328
CNC list analysis error
Check if the CNC file is correct and
redownload the program.
3029
12329
CNC file analysis error
Check if the CNC file is correct and
redownload the program.
302A
12330
Cam file parsing failed.
Check if the cam file is correct. Contact local
technicians if the problem still exists after re-
downloading the program.
3031
12337
Source code file parsing failed.
Check if the source code file is correct.
Contact local technicians if the problem still
exists after re-downloading the program.
3050
12368
The actual time for executing the
priority 0 task exceeds the set
watchdog timeout time.
Contact local distributors
3051
12369
The actual time for executing the
priority 1 task exceeds the set
watchdog timeout time.
1.
Reset the watchdog time to a larger
value for the task.
2.
Check whether there is any infinite loop
in the program which the task calls.
3.
Redownload it after modifying the
program.
3052
12370
The actual time for executing the
priority2 task exceeds the set
watchdog timeout time.
1.
Reset the watchdog time to a larger
value for the task.
2.
Check whether there is any infinite loop
in the program which the task calls.
3.
Redownload it after modifying the
program.
3053
12371
The actual time for executing the
priority 3 task exceeds the set
watchdog timeout time.
1.
Reset the watchdog time to a larger
value for the task.
2.
Check whether there is any infinite loop
in the program which the task calls.
3.
Redownload it after modifying the
program.
3054
12372
The actual time for executing the
priority 4 task exceeds the set
watchdog timeout time.
1.
Reset the watchdog time to a larger
value for the task.
2.
Check whether there is any infinite loop
in the program which the task calls.
3.
Redownload it after modifying the
program.
3055
12373
The actual time for executing the
priority 5 task exceeds the set
watchdog timeout time.
1.
Reset the watchdog time to a larger
value for the task.
2.
Check whether there is any infinite loop
in the program which the task calls.
3.
Redownload it after modifying the
program.
3056
12374
The actual time for executing the
priority 6 task exceeds the set
watchdog timeout time.
1.
Reset the watchdog time to a larger
value for the task.
2.
Check whether there is any infinite loop
in the program which the task calls.
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...