Chapter 8 Logic Instructions
8-281
8_
String Processing Instructions
FB/FC
Explanation
Applicable
model
FC
CONCAT joins two or more string variables or constants together to form a
new string.
DVP15MC11T
DVP15MC11T-06
.
Parameters
Parameter
name
Meaning
Input/ Output
Description
Valid range
In1 to InN
Strings to join
Input
The joined
parameter can be
added or removed
while the program
is being written.
The maximum
number of joined
parameters is 8
and the minimum
number is 2.
N=2~8.
Depends on the data type of the
variable that the input parameter is
connected to.
Out
Result of joining
Output
String resulted
from joining
Depends on the data type of the
variable that the output parameter is
connected to.
B
oo
le
an
Bit string
Integer
Real
number
Time, date
S
tr
in
g
B
OOL
BYT
E
WO
R
D
DW
O
RD
LW
O
R
D
US
INT
UI
NT
UDI
NT
UL
INT
SI
N
T
IN
T
DI
NT
LI
N
T
R
EA
L
L
R
E
AL
T
IME
D
AT
E
T
O
D
DT
S
T
RI
NG
In1
to
InN
●
Out
●
Note:
The symbol
●
indicates that the parameter is allowed to connect to the variable or constant of the data
type.
CO NCAT
EN
ENO
In1
Ou t
InN
.
.
.
.
.
.
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...