DVP-15MC Series Motion Controller Operation Manual
11-350
11
1
2. See the motion curve and timing chart of the terminal actuator.
Y axis
(
,
)
100000
100000
X ax is
LIN ABS1
(
,
)
250000
100000
LIN AB S1_Ex
LIN ABS1_Abt
LIN ABS 1_D one
LIN ABS1_Er r
LIN ABS1_Bs y
LINA BS1_Act
LIN ABS2_Abt
LIN ABS 2_D one
LIN ABS2_Er r
LIN ABS2_Bs y
LINA BS2_Act
LIN ABS2
0
Set BufferMode to mcBlendingPrevious and TransitionMode to mcTMConstantVelocity for LINABS2.
The values of LINABS1_Pos [1] and LINABS1_Pos [2] of LINABS1 are both set to 100,000. And the
values of LINABS2_Pos [1] and LINABS2_Pos [2] of LINABS2 are set to 250,000 and 100,000
respectively.
ADDAXIS1 and ADDAXIS2 are executed first and then DMC_GroupEnable0 is executed. When the
axes group is enabled, LINABS1 is excecuted and then LINABS2 is executed immediately.
When the terminal actuator gets to the coordinates (100,000, 100,000), LINABS1_Done changes to
TRUE. Meanwhile LINABS2_Act changes to TRUE and LINABS2 starts to execute. At the moment,
the speed of the termnial actuator is the target speed 20, 000 of the previous instruction.
The terminal actuator conducts the smooth transition and then makes a linear motion after LINABS2
is executed. The instruction execution is completed once the terminal actuator reaches the
coordinates (250,000, 100,000).
Programming Example 3
The example in which there are two DMC_MoveLinearAbsolute instructions and the transition mode
between them is mcTMCornerDistance is as follows.
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...