Chapter 11 Motion Control Instructions
11-395
11
Name
Timing for changing to TRUE
Timing for changing to FALSE
the instruction are illegal.
Output Update Timing Chart
En able
Valid
Bus y
Error
E rro r ID
Cas e1
Cas e
2
Case 1
:
When
Enable
changes from FALSE to TRUE,
Busy
changes to TRUE. One cycle later,
Valid
changes to TRUE. When
Enable
changes from TRUE to FALSE,
Valid
and
Busy
change to
FALSE simultaneously.
Case 2
:
When there is an input error in the instruction and
Enable
changes from FALSE to TRUE, Busy
changes to TRUE, one cycle later,
Error
changes to TRUE and
ErrorID
shows error codes and
meanwhile
Busy
changes to FALSE. When
Enable
changes from TRUE to FALSE,
Error
changes to FALSE and the value in
ErrorID
is cleared to 0.
Function
DMC_GroupReadActualPosition instruction is used to read current positions of axes in the axes group.
The value of the output
Position
is an array. Every member of the array corresponds to one axis
position. E.g. Position[1] corresponds to the position on X-axis, Position[2] corresponds to the position
on Y-axis and so on. The firmware of V1.01 and above supports the function.
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...