DVP-15MC Series Motion Controller Operation Manual
8-16
_8
Programming Example
The variable table and program
Variable name
Data type
Initial value
SR1
SR
SR1_EN
BOOL
FALSE
SR1_SET
BOOL
FALSE
SR1_Reset
BOOL
FALSE
SR1_Q
BOOL
Timing Chart:
Case 1
:
When SR1_SET is TRUE, SR1_Q is TRUE. When SR1_Reset is TRUE, SR1_Q is
FALSE.
Case 2
:
SR1_SET is given the priority when SR1_SET and SR1_Reset are both TRUE.
1
S R
EN
ENO
SE T
Q
1
Res et
S R1 _EN
S R1_SET
SR1_Res et
SR1_Q
SR
SR1_SE T
SR1_Res et
SR1_Q
Cas e 1
Cas e 2