Function code
Indication
Max. number of
writable/readable
registers
Available
register
16#01
Read output bit register values.
256
Bit register
16#02
Read bit register values.
256
Bit register
16#03
Read one single or multiple word register
values.
100
Word register
16#05
Write one single bit register value.
1
Bit register
16#06
Write one single word register value.
1
Word register
16#0F
Write multiple bit register values.
256
Bit register
16#10
Write multiple word register values.
100
Word register
Exception
response
code
Indication
16#01
Unsupported function code
16#02
Unsupported Modbus address
16#03
The data length is out of the valid range.
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...