Chapter 11 Motion Control Instructions
11-183
11
Name
Timing for changing to TRUE
Timing for changing to FALSE
Busy
When
Execute
changes to TRUE
When the acyclic cam motion is
performed (
Periodic
=FALSE) and
EndOfProfile
changes to TRUE
When
Error
changes to TRUE
When
CommandAborted
changes to
TRUE
Active
When the instruction starts to control
axes
When the acyclic cam motion is
performed (
Periodic
=FALSE) and
EndOfProfile
changes to TRUE
When
Error
changes to TRUE
When
CommandAborted
changes to
TRUE
CommandAb
orted
When the instruction execution is
aborted by other motion instruction
When
Execute
changes from TRUE to
FALSE
CommandAborted
is set to TRUE when
the instruction is aborted by other
instruction after
Execute
changes from
TRUE to FALSE in the course of the
instruction execution. One period later,
CommandAborted
changes to FALSE.
Error
When an error occurs in the instruction
execution or the input parameters for
the instruction are illegal
When
Execute
changes from TRUE to
FALSE
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...