Chapter 11 Motion Control Instructions
11-325
11
Name
Timing for changing to TRUE
Timing for changing to FALSE
CommandAborted
When the instruction execution is
aborted.
When
Execute
changes from TRUE to
FALSE.
Error
When an error occurs in the
instruction execution or the input
parameters for the instruction are
illegal.
When
Execute
changes from TRUE to
FALSE.
Output Update Timing Chart
Execute
Done
Busy
Com m andA bort
Er ror
Er ror ID
Case 1
Case 2
Case 3
Case 1
:
When
Execute
changes from FALSE to TRUE,
Busy
changes to TRUE. When the axes
group is paused successfully,
Done
changes to TRUE and
Busy
changes to FALSE. When
Execute
changes from TRUE to FALSE,
Done
changes to FALSE.
Case 2
:
When the instruction execution is aborted,
CommandAborted
changes to TRUE and
Busy
changes to FALSE. When
Execute
changes to FALSE,
CommandAborted
changes to
FALSE.
Case 3
:
When an error occurs in the course of the instruction execution,
Error
changes to TRUE and
ErrorID
shows the corresponding error code. Meanwhile,
Busy
changes to FALSE.
Error
changes to FALSE and the value in
ErrorID
is cleared to 0 when
Execute
changes to FALSE.
Function
DMC_GroupInterrupt is used to pause the motion of the current axes group for a period of time.
1. The input parameters
Deceleration
and
Jerk
of the DMC_GroupInterrupt instruction are reserved and
the input values for them are invalid. When the DMC_GroupInterrupt instruction is executed, the PLC
will decelerate at the deceleration rate of the axes group instruction controlling the motion of the axes
group until the axes group stops running.
2. The DMC_GroupInterrupt instruction can be executed only while the axes group instructions
DMC_MoveDirectAbsolute,
DMC_MoveDirectRelative,
DMC_MoveLinearAbsolute,
DMC_MoveLinearRelative, DMC_MoveCircularAbsolute and DMC_MoveCircularRelative are being
executed normally.
3. DMC_GroupContinue can be used to restore the axes group to the state before being paused after
DMC_GroupInterrupt is executed.
4. The execution results are consistent when several DMC_GroupInterrupt instructions are executed
simultaneously.
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...