DVP-15MC Series Motion Controller Operation Manual
8-34
_8
Precautions for Correct Use
The input variables are not allowed to omit. An error will occur during the compiling of the software
if any input variable is omitted. But the output variable is allowed to omit.
The data type of output variables must be BOOL. Otherwise, an error will occur during the
compiling of the software.
Programming Example
The data types of LE_In1, LE_In2 and LE_In3 are INT, UINT and DINT respectively and the
data type of Out1 is BOOL.
Out1 changes to TRUE when the values of LE_In1, LE_In2 and LE_In3 are -10, 50 and 50
respectively and LE_EN changes to TRUE as shown in Variable 1.
Out1 changes to FALSE when the values of LE_In1, LE_In2 and LE_In3 are 20, 10 and 100
respectively and LE_EN changes to TRUE as shown in Variable 2.
Variable 1
Variable name
Data type
Current value
LE_EN
BOOL
TRUE
LE_In1
INT
-10
LE_In2
UINT
50
LE_In3
DINT
50
Out1
BOOL
TRUE
Variable 2
Variable name
Data type
Current value
LE_EN
BOOL
TRUE
LE_In1
INT
20
LE_In2
UINT
10
LE_In3
DINT
100
Out1
BOOL
FALSE
The Program
The data types of LE_In1 and LE_In2 are both TIME and the data type of Out1 is BOOL.
Out1 changes to TRUE when the values of LE_In1 and LE_In2 are T#1ms and T#50ms
respectively and LE_EN is TRUE.
The variable table and program
Variable name
Data type
Current value
LE_EN
BOOL
TRUE
LE_In1
TIME
T#1ms
LE_In2
TIME
T#50ms
Out1
BOOL
TRUE
1
LE
EN
ENO
I n1
O ut
I n3
I n2
LE _EN
L E_In1
L E_In3
L E_In2
Out 1
1
LE
EN
ENO
I n1
O ut
I n2
LE _EN
L E_In1
L E_In2
Out 1
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...