Chapter 8 Logic Instructions
8-309
8_
Output Update Timing Chart
Case 1
:
When
Enable
changes from FALSE to TRUE and
Open
is FALSE,
Valid
changes to TRUE and
LinkOpened is FALSE.
Case 2
:
In the situation that
Enable
changes from FALSE to TRUE and
Valid
changes to TRUE,
LinkOpened
changes to TRUE as
Open
changes from FALSE to TRUE.
Valid
and
LinkOpened
change to FALSE as
Enable
changes from TRUE to FALSE.
Case 3
:
When
Open
is TRUE and
Enable
changes from FALSE to TRUE,
Valid
and
LinkOpened
change
to TRUE. When
Open
changes to FALSE,
LinkOpened
changes to FALSE.
Function
1.
The firmware of V1.11 major version and above as well as that of V1.04 minor version and above
support the instruction function.
2.
When DVP04AD-SL and DVP04DA-SL modules are connected to the left side of DVP-50MC/15MC
series motion controller, the Left_Manage instruction can be used to enable or disable the function
of the left-side module device mapping. While
Enable
is TRUE, the function of the left-side module
device mapping is turned ON if
Open
is TRUE. The function of the left-side module device mapping
is turned OFF if
Open
is FALSE.
3.
The function of the left-side module device mapping is disabled by default for one PLC. The function
of the left-side module device mapping can not be used until the Left_Manage instruction is re-
executed to enable the function after the function is enabled and the PLC is power ON again.
4.
See the following input and output areas for the modules at different positions of the PLC when DVP-
50MC/15MC series PLC connects modules at its left side. The position of the first module at the left-
side of the PLC is 1 and the second one is 2 and so on. The positions of all modules at the left side
of the PLC can be counted in order.
No matter whether the device mapping function is enabled or not by the instruction, the calculation
method for the left-side module position is identical.
The mapping device area for AD modules is the input mapping area and the mapping device area
for DA modules is the output mapping area
Mapping
area
Position
Output mapping area
Input mapping area
1
%MW6250~%MW6377
%MW6000~%MW6127
2
%MW6750~%MW6877
%MW6500~%MW6627
3
%MW7250~%MW7377
%MW7000~%MW7127
Enable
Open
Valid
LinkOpened
Case 1
Case 3
Case 2
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...