Remote Commands in the Receiver Application
R&S
®
ESW
650
User Manual 1177.6298.02 ─ 08
Example:
INST:COUP:CENT ALL
Synchronizes the receiver (or center) frequency.
Manual operation:
See
"Synchronizing parameters across all measurement chan-
INSTrument:COUPle:DEMod
<State>
This command turns synchronization of the output configuration between measure-
ment channels on and off.
Parameters:
<State>
ALL | 1
Turns on synchronization.
NONE | 0
Turns off synchronization.
*RST:
NONE
Example:
INST:COUP:DEM ALL
Synchronizes the output configuration.
INSTrument:COUPle:GAIN
<State>
This command turns synchronization of the preamplifier configuration between mea-
surement channels on and off.
Parameters:
<State>
ALL | 1
Turns on synchronization.
NONE | 0
Turns off synchronization.
*RST:
NONE
Example:
INST:COUP:GAIN ALL
Synchronizes the preamplifier configuration.
Manual operation:
See
"Synchronizing parameters across all measurement chan-
INSTrument:COUPle:LLINes
<State>
INSTrument:COUPle:LIMit
<State>
This command turns synchronization of limit lines between measurement channels on
and off.
Parameters:
<State>
ALL | 1
Turns on synchronization.
Limit lines have to be compatible to the x-axis and y-axis config-
uration for successful synchronization.
General Instrument Setup