Remote Commands in the Receiver Application
R&S
®
ESW
499
User Manual 1177.6298.02 ─ 08
OUTPut<ou>:LINK
<Scope>
This command selects the scope of the output settings.
Suffix:
<ou>
.
irrelevant
Parameters:
<Scope>
ON | 1
Output settings apply to the current measurement channel.
OFF | 0
Output settings apply to all measurement channels.
Example:
//Apply output configuration to all measurement channels
OUTP:LINK OFF
Manual operation:
See
[SENSe:]DEMod:SQUelch:LEVel
<Level>
This command defines the squelch level for audio output, below which the output is not
demodulated.
If you are using the "Marker Demodulation" marker function in the spectrum applica-
tion, the command instead selects the level below which the signal at the marker posi-
tion is not demodulated.
Parameters:
<Level>
<numeric value>
Default unit: PCT
Example:
//Configure squelch for audio output
DEM:SQU ON
DEM:SQU:LEV 10
Manual operation:
See
[SENSe:]DEMod:SQUelch[:STATe]
<State>
This command turns a squelch for the audio output on and off.
The squelch is available for the following outputs.
●
AM
●
FM
If you are using the "Marker Demodulation" marker function in the spectrum applica-
tion, the command instead turns selective demodulation at the marker position on and
off. For selective demodulation, the R&S
ESW turns on a video trigger whose level cor-
responds to the squelch level. Therefore it turns off other triggers or gates.
In both cases, you can define the squelch level with
.
Configuration