![Rohde & Schwarz ESW Series User Manual Download Page 460](http://html.mh-extra.com/html/rohde-and-schwarz/esw-series/esw-series_user-manual_1477816460.webp)
Remote Commands in the Receiver Application
R&S
®
ESW
460
User Manual 1177.6298.02 ─ 08
Parameters:
<Range>
<numeric value> (integer only)
Number of ranges in the scan table.
If you enter the value "0", the R&S
ESW ignores the configura-
tion of the scan table. Instead, it performs the measurement
based on the current receiver configuration.
Range:
0 to 100
*RST:
2
Example:
//Define number of scan ranges
SCAN:RANG:COUN 4
Manual operation:
See
"Adding and removing scan ranges"
[SENSe:]SCAN<sr>:STARt
<Frequency>
This command defines the start frequency of a scan range.
Suffix:
<sr>
.
Selects the scan range.
Parameters:
<Frequency>
<numeric value>
Range:
Refer to the datasheet
*RST:
Depends on the scan range.
Default unit: Hz
Example:
//Define start frequency for 4th scan range
SCAN4:STAR 30MHz
Manual operation:
See
[SENSe:]SCAN<sr>:STEP
<Frequency>
This command defines the frequency stepsize applied in the selected scan range
Available for linear and logarithmic step mode (
Suffix:
<sr>
.
Selects the scan range.
Parameters:
<Frequency>
<numeric value>
Linear
step mode: numeric value in %.
Logarithmic
step mode: numeric value in Hz.
*RST:
Depends on the scan and frequency range.
Default unit: HZ
Example:
//Define step size for 4th scan range
SWE:SPAC LIN
SCAN4:STEP 100KHZ
Manual operation:
See
Measurements and Result Displays