Common Measurement Settings
R&S
®
ESW
178
User Manual 1177.6298.02 ─ 08
Signal Tracking
Access
: "Overview" > "Frequency" > "Signal Tracking" tab
Defines the settings for signal tracking. These settings are only available for spans > 0.
If activated, after each sweep, the center frequency is set to the maximum level of the
specified "Signal Track Trace" found within the searched "Tracking Bandwidth".
If the signal level does not pass the "Tracking Threshold", the center frequency is not
changed.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:STRack[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:STRack:BANDwidth
CALCulate<n>:MARKer<m>:FUNCtion:STRack:THReshold
CALCulate<n>:MARKer<m>:FUNCtion:STRack:TRACe
10.8.2
Frequency and Span Settings
Access
(general frequency settings): "Overview" > "Frequency" > "Frequency"
Access
(signal tracking): "Overview" > "Frequency" > "IF Signal Tracking"
Synchronizing the receiver frequency to the marker frequency
................................................................................................ 179
........................................................................................... 180
Receiver Frequency
Defines the receiver frequency.
For a scan, make sure to define a frequency that is at least twice as large as the reso-
lution bandwidth. If you use a frequency that is lower, the R&S
ESW automatically
reduces the bandwidth.
Note that turning on the low noise preamplifier limits the lower frequency to 150
kHz.
Tip:
In the scan diagram, you can add a vertical line that represents the frequency that
the R&S
ESW is currently tuned to (
, available in the "Lines" menu).
Frequency and Span Configuration