Remote Commands in the Receiver Application
R&S
®
ESW
495
User Manual 1177.6298.02 ─ 08
If the user port is programmed to input instead of output (see
on page 494), the output value is temporarily stored.
Suffix:
<up>
.
irrelevant
Parameters:
<Value>
bit values in hexadecimal format
TTL type voltage levels (max. 5V)
Range:
#B00000000 to #B00111111
Example:
OUTP:UPOR #B00100100
Sets pins 5 and 7 to 5 V.
Manual operation:
See
OUTPut<up>:UPORt:STATe
<State>
This command toggles the control lines of the user ports for the
AUX PORT
connector.
This 9-pole SUB-D male connector is located on the rear panel of the R&S
ESW.
Suffix:
<up>
.
irrelevant
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
User port is switched to INPut
ON | 1
User port is switched to OUTPut
Example:
OUTP:UPOR:STAT ON
Manual operation:
See
15.6.2
Output Configuration
......................................................................................495
15.6.2.1
IF / Video / Demodulation
.............................................................................................. 496
......................................................................................... 496
OUTPut<ou>:IF:LPASs:FREQuency:MANual
....................................................................497
.......................................................................................497
...................................................................................... 498
..............................................................................................498
.....................................................................................499
Configuration