SYSTem:COMMunicate:RDEVice:GENerator<gen>:LINK
.................................................. 492
SYSTem:COMMunicate:RDEVice:GENerator<gen>:TYPE
................................................. 493
SYSTem:COMMunicate:TCPip:RDEVice:GENerator<gen>:ADDRess
................................. 493
SOURce<si>:EXTernal<gen>:FREQuency
<Frequency>
This command defines a fixed source frequency for the external generator.
Suffix:
<si>
.
irrelevant
<gen>
Parameters:
<Frequency>
Source frequency of the external generator.
*RST:
1100050000
Default unit: HZ
Example:
//Define frequency of the generator
SOUR:EXT:FREQ 10MHz
Manual operation:
See
SOURce<si>:EXTernal<gen>:FREQuency:COUPling[:STATe]
<State>
This command couples the frequency of the external generator output to the
R&S
ESW.
Suffix:
<si>
.
irrelevant
<gen>
Parameters:
<State>
ON | OFF | 0 | 1
ON | 1
Default setting: a series of frequencies is defined (one for each
sweep point), based on the current frequency at the RF input of
the R&S
ESW; the RF frequency range covers the currently
defined span of the R&S
ESW (unless limited by the range of
the signal generator)
OFF | 0
The generator uses a single fixed frequency, defined by
SOURce<si>:EXTernal<gen>:FREQuency
*RST:
1
Example:
SOUR:EXT:FREQ:COUP ON
Manual operation:
See
SOURce<si>:EXTernal<gen>:FREQuency[:FACTor]:DENominator
<Value>
This command defines the denominator of the factor with which the analyzer frequency
is multiplied in order to obtain the transmit frequency of the selected generator.