Remote Commands in the Receiver Application
R&S
®
ESW
458
User Manual 1177.6298.02 ─ 08
[SENSe:]SCAN<sr>:INPut:GAIN:LNA:AUTO
<State>
This command includes and excludes the optional low noise amplifier from the auto
ranging feature.
This command is available with the optional low noise amplifier.
Suffix:
<sr>
.
Selects the scan range.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Example:
//Automatic selection if amplifier is used or not
SCAN1:INP:GAIN:LNA:AUTO ON
Manual operation:
See
[SENSe:]SCAN<sr>:INPut:GAIN:LNA:STATe
<State>
This command turns the optional low noise amplifier on and off.
Note that it is not possible to use the low noise amplifier and the preamplifier at the
same time.
Suffix:
<sr>
.
Selects the scan range.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Example:
//Turn on low noise amplifier
SCAN:INP:GAIN:LNA:STAT ON
Manual operation:
See
[SENSe:]SCAN<sr>:INPut:GAIN:STATe
<State>
This command turns the preamplifier in a scan range on and off.
The command is available with the optional preamplifier.
Suffix:
<sr>
.
Selects the scan range.
Parameters:
<State>
ON | 1
Turns on the preamplifier.
OFF | 0
Turns off the preamplifier.
*RST:
OFF
Measurements and Result Displays