Remote Commands in the Receiver Application
R&S
®
ESW
545
User Manual 1177.6298.02 ─ 08
Example:
CALC:THR -82DBM
Sets the threshold value to -82 dBm.
Manual operation:
See
CALCulate<n>:THReshold:STATe
<State>
This command turns a threshold for the marker peak search on and off (for
all
markers
in
all
windows).
Suffix:
<n>
.
irrelevant
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:THR:STAT ON
Switches on the threshold line.
Manual operation:
See
"Deactivating All Search Limits"
15.7.4.4
Marker Positioning
Markers
CALCulate<n>:MARKer<m>:MAXimum:LEFT
...................................................................545
CALCulate<n>:MARKer<m>:MAXimum:NEXT
.................................................................. 546
CALCulate<n>:MARKer<m>:MAXimum[:PEAK]
................................................................ 546
CALCulate<n>:MARKer<m>:MAXimum:RIGHt
..................................................................546
CALCulate<n>:MARKer<m>:MINimum:LEFT
....................................................................546
CALCulate<n>:MARKer<m>:MINimum:NEXT
................................................................... 547
CALCulate<n>:MARKer<m>:MINimum[:PEAK]
................................................................. 547
CALCulate<n>:MARKer<m>:MINimum:RIGHt
...................................................................547
CALCulate<n>:MARKer<m>:MAXimum:LEFT
This command moves a marker to the next lower peak.
The search includes only measurement values to the left of the current marker posi-
tion.
In the spectrogram, the command moves a marker horizontally to the maximum level in
the currently selected frame. The vertical marker position remains the same.
Suffix:
<n>
.
Analysis