Remote Commands in the Receiver Application
R&S
®
ESW
486
User Manual 1177.6298.02 ─ 08
Manual operation:
See
15.6.1.2
Preselector Configuration
INPut<ip>:ATTenuation:LIMiter[:STATe]
............................................................................ 486
INPut<ip>:PRESelection:FILTer:NOTCh<notch>[:STATe]
....................................................486
INPut<ip>:PRESelection:FILTer:SPLit[:STATe]
...................................................................487
INPut<ip>:PRESelection[:STATe]
..................................................................................... 487
INPut<ip>:ATTenuation:LIMiter[:STATe]
<State>
This command turns the pulse limiter on and off.
The pulse limiter is an additional protection mechanism for the second RF input that
attenuates high level pulses.
Suffix:
<ip>
.
irrelevant
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
ON
Example:
//Turn on pulse limiter
INP:ATT:LIM ON
Manual operation:
See
INPut<ip>:PRESelection:FILTer:NOTCh<notch>[:STATe]
<State>
This command turns a preselecting notch filter on and off.
Suffix:
<ip>
.
irrelevant
<notch>
1..2
Selects the filter.
•
<1> Selects the notch filter suppressing signals from 2.4
GHz
to 2.5
GHz.
•
<2> Selects the notch filter suppressing signals from
2.725
GHz to 2.875
GHz.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Example:
//Turn on notch filter for frequencies from 2.725
GHz to
2.875
GHz.
INP:PRES:FILT:NOTC2 ON
Manual operation:
See
Configuration