
Measurements and Result Displays
R&S
®
ESW
128
User Manual 1177.6298.02 ─ 08
Allows you to add a comment to each peak as required (only possible after a peak
search has been done).
●
Deletes the corresponding row from the peak list.
The remote commands required to edit the peak list are described in
Adding the current frequency to the peak list
................................................128
...................................................................................... 129
Editing a peak list
The R&S
ESW allows you to edit a peak list that has been created, or even create a
peak list that is not based on an automatic peak search.
●
Adding a new frequency
To add a new peak to the peak list, enter a
frequency
in the corresponding field
and add it to the list with the "Insert" button.
Tip:
Alternatively, you can add the current receiver frequency including the mea-
softkey.
The new frequency is added to the list regardless if the level threshold conditions
have been fulfilled for that frequency.
Note that the frequency has to be in the displayed frequency range.
●
Deleting a frequency
To remove a peak from the peak list, select the corresponding peak list row and
delete it with the "Delete Peak Entry" button.
Alternatively, use the
button in the peak list itself.
You can also delete the complete peak list with the "Clear All Entries" button.
Remote command:
Add frequency:
Clear list:
CALCulate<n>:PEAKsearch:CLEar[:IMMediate]
Adding the current frequency to the peak list ← Editing a peak list
The receiver application allows you to add the current receiver frequency manually to
the peak list.
To add the current receiver frequency to the peak list, proceed as follows:
●
Use the "Add to Peak List" softkey available in the "Meas Config" or the "Marker
Function" softkey menu.
●
Use the "Add to Peak List" button available in the "Peak List" result display.
Remote command:
Sorting the peak list
By default, the R&S
ESW sorts the peaks by their "Frequency" in ascending order.
Alternatively, you can sort the peak list by the distance of a peak to the limit line (
➙
"Delta Limit"). This is also done in ascending order.
Sorting by the delta limit is available when a limit line is active and evaluated.
Test Automation