![Rohde & Schwarz ESW Series User Manual Download Page 211](http://html.mh-extra.com/html/rohde-and-schwarz/esw-series/esw-series_user-manual_1477816211.webp)
Common Analysis and Display Functions
R&S
®
ESW
211
User Manual 1177.6298.02 ─ 08
11.3.2
Trace Configuration
A trace is a collection of measured data points. The trace settings determine how the
measured data is analyzed and displayed on the screen.
Trace configuration for the scan diagram
The contents of the "Traces" tab of the "Trace Configuration" are the same as the
tab of the "Test Automation" dialog box.
Trace configuration for IF analysis
IF analysis supports a maximum of three traces. The "Traces" dialog box available for
IF analysis supports the following functions:
●
●
"Predefined Trace Settings - Quick Config"
Additional trace configuration features
In addition, the "Trace Configuration" for scans provides the following functionality.
Predefined Trace Settings - Quick Config
................................................................... 211
Predefined Trace Settings - Quick Config
Commonly required trace settings have been predefined and can be applied very
quickly by selecting the appropriate button.
Function
Trace Settings
Preset All Traces
Trace 1:
Clear Write
Blank
Set Trace Mode
Max | Avg | Min
Trace 1:
Max Hold
Trace 2:
Average
Trace 3:
Min Hold
Blank
Set Trace Mode
Max | ClrWrite | Min
Trace 1:
Max Hold
Trace 2:
Clear Write
Trace 3:
Min Hold
Blank
11.3.3
Trace Export
Access
: "Overview" > "Analysis" > "Traces" > "Trace Export"
The R&S
ESW provides various evaluation methods for the results of the performed
measurements. If you want to evaluate the data with other, external applications, you
can export the measurement data to a standard ASCII format file (
DAT
or
CSV
).
Trace Configuration