Remote Commands in the Receiver Application
R&S
®
ESW
505
User Manual 1177.6298.02 ─ 08
Suffix:
<n>
.
irrelevant
<m>
irrelevant
Parameters:
<TraceNumber>
1 to 6
Range:
1 to 6
*RST:
1
Manual operation:
See
See
DISPlay[:WINDow<n>]:TRACe<t>:X:SPACing
<Scale>
This command selects the scale of the x-axis.
Suffix:
<n>
.
irrelevant
<t>
irrelevant
Parameters:
<Scale>
LINear
Linear scale of the frequency axis.
LOGarithmic
Logarithmic scale of the frequency axis.
*RST:
LOGarithmic
Example:
//Select a linear scale for the x-axis
DISP:TRAC:X:SPAC LIN
Manual operation:
See
[SENSe:]FREQuency:CENTer
<Frequency>
This command defines the measurement frequency for measurements in the frequency
or time domain.
Parameters:
<Frequency>
<numeric value>
Numeric value in Hz.
Range:
Refer to the datasheet
*RST:
fmax / 2
Default unit: Hz
Example:
//Define receiver frequency
FREQ:CENT 100MHz
Manual operation:
See