Remote Commands in the Receiver Application
R&S
®
ESW
443
User Manual 1177.6298.02 ─ 08
Suffix:
<mt>
.
INITiate1 initiates a bargraph measurement.
INITiate2 initiates a scan.
Example:
//Start a single scan (with a scan count = 20), and wait until the
measurement is done
INIT2:CONT OFF
SWE:COUN 20
INIT2;*WAI
Usage:
Event
Manual operation:
See
"Performing continuous measurements"
See
"Performing single measurements"
15.5.2
Measurement Sequences
CONFigure:RECeiver:MEASurement[:DEFault]
.................................................................443
............................................................................................ 443
....................................................................................... 444
.............................................................................................444
CONFigure:RECeiver:MEASurement[:DEFault]
<Measurement>
This command selects the measurement performed in a receiver channel during mea-
surement sequences.
Parameters:
<Measurement>
BARGraph
Performs a bargraph measurement.
NONE
Performs no measurement.
SCAN
Performs a scan.
*RST:
SCAN
Example:
//Perform a bargraph measurement in a measurement sequence
CONF:REC:MEAS BARG
INITiate:SEQuencer:ABORt
This command stops the currently active sequence of measurements.
You can start a new sequence any time using
Usage:
Event
Manual operation:
See
Measurements and Result Displays