Remote Commands in the Receiver Application
R&S
®
ESW
478
User Manual 1177.6298.02 ─ 08
Example:
//Query level of the fourth peak
CALC:FME:PLIS4:LEV?
//Return value example:
-53.99
CALCulate<n>:FMEasurement:PLISt<pi>:SIZE?
This command queries the number of peaks measured in the final measurement.
Suffix:
<n>
.
irrelevant
<pi>
irrelevant
Return values:
<Peaks>
Example:
//Query size of peak list
CALC:FME:PLIS:SIZE
Return value example:
100
Usage:
Query only
CALCulate<n>:FMEasurement:PLISt<pi>:TRACe?
This command queries the trace that a peak measured in the final measurement is
located on.
Suffix:
<n>
.
irrelevant
<pi>
Return values:
<Trace>
String that contains the trace number.
Example:
//Query trace of the peak
CALC:FME:PLIS4:TRAC
//would return, e.g.
'TRACE1'
Usage:
Query only
CALCulate<n>:FMEasurement:PLISt<pi>[:DATA]?
This command queries the information for a peak measured in the final measurement.
Suffix:
<n>
.
irrelevant
<pi>
Return values:
<PeakResults>
List of values for the selected peak.
Measurements and Result Displays