![Rohde & Schwarz 1145.1010.04/05/06 Operating Manual Download Page 564](http://html1.mh-extra.com/html/rohde-and-schwarz/1145-1010-04-05-06/1145-1010-04-05-06_operating-manual_1477759564.webp)
CALCulate
R&S
®
ZVA/ZVB/ZVT
1145.1084.12 6.102
E-6
The measurement parameter is selected by means of the following keywords (the selection depends on
the number of test ports of the analyzer, e.g. S44 is not available on 2-port analyzers):
S11 | S12 | S13 | S14 | S21 | S22 | S23 | S24
| S31 | S32 | S33 | S34 | S41 | S42 | S43 |
S44
S-parameters
A | B | C | D
Wave quantities b1, b2, b3, b4 (received
waves)
R1 | R2 | R3 | R4
Wave quantities a1, a2, a3, a4
(reference waves)
AB | AC | AD | BA | BC | BD | CA | CB | CD |
DA | dB | DC
Ratio of wave quantities b1/b2, b1/b3, ...
, b4/b3 (received waves only)
AR1 | AR2 | AR3 | AR4 | BR1 | BR2 | BR3 | BR4
| CR1 | CR2 | CR3 | CR4 | DR1 | DR2 | DR3 |
DR4 | R1A | R1B | R1C | R1D | R2A | R2B | R2C
| R2D | R3A | R3B | R3C | R3D | R4A | R4B |
R4C | R4D
Ratio of wave quantities b1/a1, b1/a2, ...
, b4/a4, a1/b1, a1/b2, ..., A4/B4
(received waves to reference waves or
reference waves to received waves)
R1R2 | R1R3 | R1R4 | R2R1 | R2R3 | R2R4 |
R3R1 | R3R2 | R3R4 | R4R1 | R4R2 | R4R3
Ratio of wave quantities a1/a2, a1/a3, ...
, a4/a3 (reference waves only)
CALCulate<Ch>:PARameter:DELete '<string>'
Deletes a trace with a specified trace name and channel.
<Ch>
Channel number.
'<string>'
Trace name, e.g. 'Trc4'. See
Rules for trace names
in the
Trace
Manager
description.
*RST value
–
SCPI, Command
Types
Device-specific, no query.
Example:
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'
Create channel 4 and a trace named
Ch4Tr1
to measure the input
reflection coefficient S11.
CALC4:PAR:CAT?
Query the traces assigned to channel 4. If
Ch4Tr1
is the only trace
assigned to channel 4, the response is 'CH4TR1,S11'.
CALC4:PAR:DEL 'CH4TR1'
Delete the created trace.
CALCulate<Ch>:PARameter:MEASure '<string>', 'S11' | ... | 'S0101' | ... | 'SCD11'
| ... | 'Y11' | ... | 'Z11' | ... | 'SY11' | ... | 'SZ11' | ... | 'a1' | ... | 'A01' | ... | 'B1' | ... | 'B01'
| ... | 'B2/A1' | ... 'B02/A01' | ...
Assigns a measurement parameter to an
existing
trace.
Summary of Contents for 1145.1010.04/05/06
Page 10: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 70: ......
Page 72: ......
Page 90: ......
Page 92: ......
Page 108: ......
Page 156: ......
Page 162: ......
Page 406: ...Display Menu R S ZVA ZVB ZVT 1145 1084 12 4 244 E 6 Stack Tile Horizontally Tile Vertically...
Page 450: ...Status Reporting System R S ZVA ZVB ZVT 1145 1084 12 5 18 E 1...
Page 462: ......
Page 766: ......
Page 772: ......
Page 792: ......
Page 794: ......
Page 808: ......