Screen Elements
R&S
®
ZVA/ZVB/ZVT
1145.1084.12 3.18
E-1
•
Cancel
discards the current selection and closes the keyboard. The input field of the calling
dialog is left unchanged.
The on-screen keyboard allows you to enter characters, in particular letters, without an external
keyboard; see
Data Entry.
To enter numbers and units, you can also use the DATA ENTRY keys on the
front panel of the instrument.
Step Size
A step
symbol next to a numeric input field opens the
Step Size
dialog to define an increment for
data variation using the
Cursor Up/Down
buttons in the dialogs or the rotary knob.
•
The input value for the step size takes effect immediately; see
Immediate vs. Confirmed Settings.
•
Auto
activates the default step size for the current input parameter.
•
Close
closes the
Step Size
dialog.
Numeric Entry Bar
Single numeric values can be entered using the input field of the numeric entry bar. The numeric entry
bar appears just below the menu bar as soon as a function implying a single numeric entry is activated.
In contrast to dialogs, it does not hide any of the display elements in the diagram area.
The numeric entry bar contains the name of the calling function, a numeric input field including the
Cursor Up/Down buttons for data variation and a step symbol
, and a
Close
button. Besides it is
closed automatically as soon as an active display element in the diagram area is clicked or a new menu
command is activated.
Display Formats and Diagram Types
A display format defines how the set of (complex) measurement points is converted and displayed in a
diagram. The display formats in the
Trace – Format
menu use the following basic diagram types:
•
Cartesian (rectangular) diagrams are used for all display formats involving a conversion of the
measurement data into a real (scalar) quantity, i.e. for
dB Mag, Phase, Delay, SWR, Lin Mag,
Real, Imag
and
Unwrapped Phase.
•
Polar diagrams are used for the
display format
Polar
and show a complex quantity as a vector
in a single trace.
•
Smith charts are used for the display format
Smith
and show a vector like polar diagrams but
with grid lines of constant real and imaginary part of the impedance.
Summary of Contents for 1145.1010.04/05/06
Page 10: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 70: ......
Page 72: ......
Page 90: ......
Page 92: ......
Page 108: ......
Page 156: ......
Page 162: ......
Page 406: ...Display Menu R S ZVA ZVB ZVT 1145 1084 12 4 244 E 6 Stack Tile Horizontally Tile Vertically...
Page 450: ...Status Reporting System R S ZVA ZVB ZVT 1145 1084 12 5 18 E 1...
Page 462: ......
Page 766: ......
Page 772: ......
Page 792: ......
Page 794: ......
Page 808: ......