Command Reference
R&S
®
ZNC
600
User Manual 1173.9557.02 ─ 13
<SegmentTime>
Duration of the sweep in the segment. See
DWELl
, this parameter is
replaced by
<MeasDelay>
.
Range:
Depending on other channel settings. AUTO acti-
vates automatic sweep time setting in the segment,
which is equivalent to the minimum sweep time pos-
sible.
Default unit: s
<MeasDelay>
Delay for each partial measurement in the segment. See
SWTime
, this
parameter is replaced by
<SegmentTime>
.
<Unused>
Ignored parameter (for compatibility with R&S ZVR analyzers).
Should be set to the default value 0.
<MeasBandwidth>
Resolution bandwidth in the segment. See
Default unit: Hz
<LO>
POSitive | NEGative | AUTO
Position of the local oscillator frequency LO relative to the RF fre-
quency. In remote control this parameter must be set when a
sweep segment is created. See
<Selectivity>
NORMal
Selectivity of the IF filter; must be set to
NORMal
.
Example:
SEGM:ADD
Create a new sweep segment no. 1 in channel no. 1 using default
settings.
SEGM:DEF?
Query the channel settings for the new segment. A possible
response is
1000000000,2000000000,51,-300,0.0044625,0,
10000,AUTO,NORM
.
Manual operation:
See
[SENSe<Ch>:]SEGMent<Seg>:DEFine:SELect
<TimeRef>
Defines whether the sweep time of a new segment, i.e. numeric parameter no. 5 of the
command
, is entered as a segment sweep
time ("Segment Time") or as a measurement delay ("Meas Delay").
Suffix:
<Ch>
.
Channel number
<Seg>
Sweep segment number
SCPI Command Reference