Command Reference
R&S
®
ZNC
510
User Manual 1173.9557.02 ─ 13
Setting parameters:
<CalGroupName>
String parameter to specify the name of the cal group file to be
deleted. Cal group files must have the extension
*.cal
. The
directory path must not be specified; the analyzer always uses the
default cal pool directory
'C:
\Users\Public\Documents\Rohde-Schwarz\Vna\
Calibration\Data'
.
Example:
See
Usage:
Setting only
Manual operation:
See
MMEMory:LOAD:CKIT
<CalKitFile>
Loads cal kit data from a specified R&S ZNC cal kit file.
Setting parameters:
<CalKitFile>
String parameter to specify the name and directory of the loaded
cal kit file. If no path is specified the analyzer searches the current
directory, to be queried with
?
.
Note:
The loaded file must be a R&S ZNC-specific cal kit file with
the extension
*.calkit
. R&S ZVR cal kit files can be imported
using the
command.
Agilent cal kit files can be imported manually and converted into
*.calkit
files.
Example:
MMEM:LOAD:CKIT 'C:\Users\Public\Documents
\Rohde-Schwarz\Vna\Calibration\Kits\New_kit.calkit'
Load the previously created cal kit file
New_kit.calkit
from the
default cal kit directory.
... :MMEM:STOR:CKIT 'New_kit', 'C:
\Users\Public\Documents
\Rohde-Schwarz\Vna\Calibration\Kits\New_kit.calkit'
Store the data for the user-defined cal kit
Newkit
and overwrite
the cal kit file
New_kit.calkit
.
Usage:
Setting only
Manual operation:
See
MMEMory:LOAD:CKIT:SDATa
<ConnectorType>, <CalKitName>, <StandardType>,
<CalKitLabel>, <TouchstoneFile>[, <FirstPort>, <SecondPort>]
Loads cal kit data for a specific connector type, cal kit, and calibration standard from a
specified Touchstone file, assigning a label for the cal data. A restriction on the port
assignment may be defined in addition.
Setting parameters:
<ConnectorType>
String parameter containing the name of the connector type.
SCPI Command Reference