Import Trace / File...
The buttons open a dialog to load a limit line from a data or memory trace in the active
recall set or from a trace which has been stored to a file (see
Imported traces are polygonal curves with n points and n – 1 segments. The number of
points n is set via "CHANNEL > SWEEP > Sweeps > Number of Points". The n – 1
segments are appended to the current segment table for further editing. Existing limit line
segments are not overwritten.
The import dialogs contain a list of all available traces or files and the following file import
settings.
●
"Offsets" contains two input fields to define constant offset values for all imported
segments. The "Response" offset shifts all segments in vertical direction, the "Stim-
ulus" offset shifts them in horizontal direction. The offsets are added to the start and
stop values of all segments.
●
"Type" defines whether the imported segments belong to the "Upper" or "Lower" limit
line. A third option is to import the segments but disable the limit check ("Off").
Remote command:
4.2.5.3
Lines > Ripple Test
Defines ripple limits for the measurement results, visualizes them in the diagrams and
activates/deactivates the ripple limit check. A ripple test is a special type of limit test where
the maximum
difference
between the largest and the smallest response value of the
trace must not exceed the specified limit.
Ripple limit lines are available for all Cartesian diagram types (TRACE > FORMAT). For
polar diagrams, the functions of the "Ripple Test" softtool except the "Global Check" are
grayed. The ripple limit lines are hidden and the limit check is disabled when a Cartesian
trace format is replaced by a polar diagram.