Command Reference
R&S
®
ZNC
433
User Manual 1173.9557.02 ─ 13
CALCulate<Chn>:RIPPle:DISPlay[:STATe]
<Boolean>
Displays or hides all ripple limit lines (including all ranges) associated to the active trace.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
Parameters:
<Boolean>
ON | OFF - ripple limit line on or off.
*RST:
OFF
Example:
*RST; CALC:RIPP:DATA 1,1500000000, 2000000000,
3
Define and enable a ripple limit range in the stimulus range
between 1.5 GHz and 2 GHz, assigning a ripple limit of +3 dB.
CALC:RIPP:DISP ON
Show the ripple limit range in the active diagram.
Manual operation:
See
CALCulate<Chn>:RIPPle:FAIL?
Returns a 0 or 1 to indicate whether or not the global ripple limit check has failed.
Tip:
to query the result for
a single ripple limit range.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
Example:
*RST; CALC:RIPP:DATA 1, 1500000000, 2000000000,
3
Define and enable a ripple limit range in the stimulus range
between 1.5 GHz and 2 GHz, assigning a ripple limit of +3 dB.
CALC:RIPP:STAT ON; FAIL?
Switch the limit check on and query the result.
CALC:RIPP:STAT:AREA LEFT, TOP
For a subsequent check at the GUI or a hardcopy, move the info
field to the top left position.
Usage:
Query only
Manual operation:
See
CALCulate<Chn>:RIPPle:RDOMain:FORMat
<UnitRef>
Deletes the existing ripple limit ranges and (re-)defines the physical unit of the ripple limit.
The units of the stimulus values are defined via
.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
SCPI Command Reference