Command Reference
R&S
®
ZNC
427
User Manual 1173.9557.02 ─ 13
Example:
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'
Create channel 4 and a trace named
Ch4Tr1
to measure the input
reflection coefficient S
11
.
CALC4:PAR:MEAS 'Ch4Tr1', 'a1'
Change the measurement parameter of the trace and measure the
wave quantity a
1
.
CALC4:PAR:MEAS? 'Ch4Tr1'
Query the measured quantity. The response is
'A1D1SAM'
.
Manual operation:
See
CALCulate<Ch>:PARameter:SDEFine
<TraceName>, <Result>
Creates a trace and assigns a channel number, a name and a measurement parameter
to it. The trace becomes the active trace in the channel but is not displayed.
Note:
To display the trace defined via
CALCulate<Ch>:PARameter:SDEFine
, create
a diagram (
) and assign the trace to this diagram
); see example below.
changes the measurement result of an exist-
ing trace.
To select an existing trace as the active trace, use
. You can open the trace manager to obtain an overview of all channels and
traces, including the traces that are not displayed.
Tip:
This command has no query form. Use
'TraceName'
to query the measurement result of the trace.
returns a list of all defined traces.
Suffix:
<Ch>
.
Channel number. <Ch> may be used to reference a previously
defined channel. If <Ch> does not exist, it is generated with default
channel settings.
Setting parameters:
<TraceName>
Trace name, string variable, e.g. 'Trc4'. See "Rules for trace
names" in
must be unique across all channels and diagrams.
If a trace with the selected trace name already exists, the analyzer
behaves as follows: If the existing trace is assigned to the same
channel as the new trace, it is deleted. The new trace is not auto-
matically assigned to a diagram area; see note above.
If the existing trace is assigned to a different channel, no new trace
can be created. The analyzer returns an error message.
<Result>
Measurement result (string variable); see list of parameters below.
SCPI Command Reference