[SENSe<Ch>:]CORRection:COLLect:FIXTure:LMParameter[:STATe]
<Boolean>
Selects an Auto Length (and Loss) calculation or a Direct Compensation.
Suffix:
<Ch>
.
Channel number of the corrected channel. This suffix is ignored;
the setting is valid for all channels.
Parameters:
<Boolean>
1 - Auto Length (and Loss), depending on the last
[SENSe<Ch>:]CORRection:COLLect:FIXTure:
LMParameter:LOSS[:STATe]
setting
0 - Direct Compensation
*RST:
1
Example:
See
Manual operation:
See
[SENSe<Ch>:]CORRection:COLLect:FIXTure:SAVE
Completes a fixture compensation, storing and applying the acquired data.
Suffix:
<Ch>
.
Channel number of the corrected channel
Example:
See
Usage:
Event
Manual operation:
See
[SENSe<Ch>:]CORRection:COLLect:FIXTure:STARt
Prepares the analyzer for fixture compensation comprising a single or a series of fixture
compensation sweeps
(
[SENSe<Ch>:]CORRection:COLLect:FIXTure[:ACQuire]