NEAX2400 IPX Feature Programming Manual
Page 618
NDA-24297, Issue 1
R-4
Restriction from Outgoing Calls
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note
STEP 1:
ARSCN
- Sixteen different Route Restriction Classes may be constructed to either allow, deny, or toll
restrict access to the various routes of the system. Assign the RSC using Route Restriction Indexes 2
(outgoing via the Attendant Console) and 3 (Outgoing Direct).
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.