NEAX2400 IPX Feature Programming Manual
Page 198
NDA-24297, Issue 1
C-25
Call Forwarding-Intercept / Announcement
Programming (cont’d)
STEP 5:
ARRC
- If TIE Line or REMOTE ACCESS TO PBX [R-2] connection to the ANNOUNCEMENT
SERVICE Trunk is required, allow trunk-to-trunk connection using ARI-D-RES, Direct Connection.
STEP 6:
AAED
- Used to assign Announcement equipment. Assign:
TN:
Tenant Number
EQP:
Announcement Equipment Number
0: Dead Level
1: Unused Number (LCR OPR not programmed)
2: Available
3: Available
4: Outgoing Trunk Group Busy Announcement
5: Available
6: Available
7: Outgoing Route Restriction Announcement
8 ~ 15: Available for ANNOUNCEMENT SERVICE [A-15] applications.
RT, TK:
Route & Trunk number of the trunk connected to the Announcement Equipment.
C:
Duration of Connection, 0/1: Disconnection occurs in 30 seconds / the connection is held
until the station releases. See the requirements of the announcement equipment.
R:
Sending RBT, 0/1: Sending/Not sending. Normally assign data “0”.
A:
Answer Signal Sending, 0/1: No answer from Incoming trunk / Answer from Incoming
trunk. Normally assign data “0”. No answer signal is sent to the CO. Therefore the calling
party will not be billed for the call.
M:
Multiple Connection, 0/1: Single Connection / Multiple Connection. See the requirements
of the announcement equipment.
STEP 7:
ACFR
- Assignment of Call Forwarding Restriction. Upon determining which types of Call Class
Indexes (CCI) will be answered via CALL FORWARDING - INTERCEPT, for example, CCSA and
DID calls: allow those CCIs a Transfer Service Feature Index of 1, for CALL FORWARDING - ALL
CALLS, NO ANSWER, BUSY.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ALRTN
- This data must be assigned to the NCN.
Assign the logical route number to the physical route.
STEP 2:
AAEDN
- This data must be assigned to the NCN.
Assign the announcement equipment data.
UGN: User Group Number
EQP:
Announcement Equipment Number
0 = Dead Level
1 = Unused Number
2-15 = Announcement service
C:
Duration of Connection
0 = Disconnection occurs in 30 seconds
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...