Page 771
Trunk-to-Trunk Third-Party Cancellation
T-28
Programming (cont’d)
System Data 3, Index 2, Bits 4-7. Switch hook flash ends timer. To calculate this value: (1 ~ FH) x 120
msec = Timer. For both beginning and ending timers, assign 91H for 120 - 1080 msec.
FCCS Programming
No unique programming is required for the FCCS network.
Note:
System timers may be set on a network basis in ASYDN.
f (t)
Bit 0-3
Bit 4-7
0 ms
No Detection
120 ms
1080 ms Disconnection
SHF Detect