NEAX2400 IPX Feature Programming Manual
Page 596
NDA-24297, Issue 1
P-13D
Prime Line Pickup - D
term
P-13D
Prime Line Pickup - D
term
General Description
This feature allows a D
term
user to originate or answer a call from the line designated as the Primary Line by going
off-hook. It is unnecessary to press the associated line key.
Operating Procedure
Lift the handset or press the SPEAKER key; receive dial tone.
Service Conditions
1.
One Prime Line per station is allowed.
2.
Unless otherwise programmed, the MY Line is also the Prime Line.
Interactions
1.
If no data is assigned via AKYD, the MY Line will serve as the default Prime Line. If any data is assigned
in AKYD, a Prime Line must be assigned, even if the MY Line and Prime Line will be the same telephone
number.
2.
The Prime Line may be different than the MY Line. When they are different, the following features will
not operate for the Prime Line: CALL BACK [C-1], CALL PARK [C-29], DO NOT DISTURB [D-21D],
and OUTGOING TRUNK QUEUING [O-2D]. CALL FORWARDING [C-2, 3, 5, 28] features may be
set by the Attendant.
3.
CLASS OF SERVICE-INDIVIDUAL [C-15]. The Prime Line will operate according to the CLASS OF
SERVICE-INDIVIDUAL of the MY Line.
4.
STATION MESSAGE DETAIL RECORDING [S-10]. All calls originated by the Prime Line will be
recorded against the MY Line.
5.
TOLL RESTRICTION-3/6 DIGIT [T-7]. The Prime Line will operate according to the restrictions of the
MY Line.
Programming
STEP 1:
AKYD
- Assign the station according to the following parameters:
TN:
1
STN:
Station Number
TP:
Type of D
term
0/1:
PL ST, STN: Prime Line Tenant and Station
RING:
0: No Ringing
1: Ringing All Lines
2: Ringing on Prime Line Only
3: Flexible Ring Assignment, enables RG parameter.
KYN: Key Number (1-40)
KYI:
Service Index
0: Key Not Used
1: Feature Key
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...