NEAX2400 IPX Feature Programming Manual
Page 690
NDA-24297, Issue 1
S-15
Serial Call
S-15 Serial
Call
General Description
This feature allows the Attendant to arrange for a recall from a station before releasing a Central Office call to that
station. When the station subsequently disconnects from the call, the Central Office party automatically rings back
to the Attendant.
Operating Procedure
1.
Answer the incoming Central Office call.
2.
Extend the call to the desired station.
3.
Press the SERIAL CALL (SC) key; the HOLD lamp corresponding to the loop will light.
4.
The called station and incoming station are connected.
5.
The called station hangs up; the HOLD lamp and the ATND lamp on the Attendant Console flash at 60
IPM. If the Attendant position is available, an audible indication will be provided.
6.
Press the associated loop key to return to the incoming calling party.
Service Conditions
1.
This service feature is effective only for incoming calls from external trunks.
2.
If the Attendant enters a loop that is already set up for SERIAL CALL, the service is automatically
cancelled.
3.
SERIAL CALL (SC) is not provided for station-to-station calling.
4.
SERIAL CALL can be provided on a per-tenant basis.
5.
SERIAL CALLING is allowed when a station is involved in an ATTENDANT CONTROLLED
CONFERENCE [A-2].
6.
STATION MESSAGE DETAIL RECORDING (SMDR) [S-10]: The duration of the total call is recorded
on the last station call.
7.
When the ATTENDANT LOCKOUT [A-5] feature is provided, the Attendant cannot reenter the
connection without being recalled.
8.
This feature is not applicable for tandem connections.
9.
In the Loop Release system, once this service is set, the attendant position enters the idle state, and the
established call is released from the loop, enabling all hooking services at the extension side. ASYD,
System Data 1, Index 186, bit 4 = 1.
10.
The Attendant sets this service by pressing the SC key when the extension user answers.
11.
It is not possible to release this service once it is set.
12.
If the operator presses the SC key before the called extension answers (Non-Delay mode service setting),
the external calling party receives a ringback tone, and the Attendant position enters the idle state.
13.
In the Non-Delay mode service, setting the extension loop release does not occur until the called extension
answers, even though the Loop Release system is specified by the system data setting (System Data 2
Index 2 b5 = 1). The operator is allowed to reenter the connection before the extension answers, though
the SERIAL CALL service remains set.
14.
CALL PICKUP GROUP [C-7] feature can be used for answering a call handled by the operator in the
Non-Delay service setting mode.
15.
CALL FORWARDING-DON’T ANSWER [C-3] feature cannot be used if SERIAL CALL is set.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...