NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 53
Attendant-To-Attendant Calling
A-60
A-60 Attendant-To-Attendant
Calling
General Description
This feature permits an Attendant, via an ATTENDANT CONSOLE [A-3], to access a non-specific free Attendant
by dialing the operator access code, or to call a particular ATTENDANT CONSOLE [A-3] by dialing an individual
Attendant Identification Number.
Operating Procedure
1.
Press an idle loop key.
2.
Dial the individual Attendant Identification Number or operator call code.
Service Conditions
1.
An Attendant Identification Number must be published for each Attendant.
2.
ATTENDANT NIGHT TRANSFER [A-19] cannot be activated for calls via this feature.
3.
The operator call code should be a 1-digit number. Normally, 0 is assigned as the operator call code.
4.
No operation keys on the called Attendant Console can be used while performing ATTENDANT-TO-
ATTENDANT CALLING.
5.
Only the CANCEL key on the calling ATTENDANT CONSOLE [A-3] can be used to disconnect
ATTENDANT-TO-ATTENDANT CALLING.
6.
An Attendant can receive only one ATTENDANT-TO-ATTENDANT CALL at a time. An INCOMING
CALL IDENTIFICATION (ICI) [I-2] key can be designated for receipt of TF: INTER-POSITION
TRANSFER CALLs and ATTENDANT-TO-ATTENDANT CALLs.
7.
An Attendant cannot extend ATTENDANT-TO-ATTENDANT CALL to any other destination.
8.
With an Individual Attendant Identification Number, an Attendant Console/Desk Console within an FCCS
network can be specified.
9.
When the operator call code is dialed, the call is routed to the predetermined Attendant Console designated
by the ASPAL command.
10.
When assigning Function Code (FUNC) to KYN1 of an Attendant Console by AAKP command, this
feature cannot be used.
Programming
STEP 1:
ASYD
- SYS1, Index 9. Assign the number of Attendant Consoles / Desk Consoles.
STEP 2:
ASPA
- Assign SRV=SSC, SID=2 (Operator Call).
STEP 3:
ASAT
- Assign identification numbers to the specific Attendant Consoles.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note
STEP 1:
ASYDN
- SYS1, Index 9. Assign the number of Attendant Consoles / Desk Consoles.
STEP 2:
ASPAL
- This command must be set to all the nodes (accommodates the Attendant Console). Assign
SRV = SSC, SID = 2 (Operator Call), FPC of the node that operator calls are to be terminated to.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...