NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 801
Asynchronous Data Switching - CCIS
A-44
Programming (cont’d)
16: Data Terminal Via Data Module
18: Virtual Circuit
19: TMM
20: PSM
23: ISDN Terminal
27: Eight Conference Equipment
RSC:
Route Restriction Class (0-15)
For assignment of RSC, ARSC command
SFC:
Service Feature Class (0-15)
For assignment of SFC, ASFC command
STEP 2:
AKYD
- Despite the fact that a station number is assigned in ASDT for the data number, only the voice
station number must be assigned to the D
term
. Assign the DATA and DTX key. The AUTO key is an
optional assignment. Assign as follows:
TN:
1
STN:
Station Number
TP:
Type of D
term
0/1:
RING:
0: No Ringing
1: Ringing All Lines
2: Ringing on Prime Line Only
3: Flexible Ring Assignment, enables RG parameter
KYN:Key Number (1 - 40)
KYI:
Service Index
0: Key Not Used
1: Feature Key
2: Multi-line Key
KD:
Assign as 0
FKY: Feature Key Number
RG:
Ringing Assignment per Multi-line Appearance
0: No Ringing
1: Ringing in Day Mode Only
2: Ringing in Night Mode Only
3: Ringing Day and Night
The feature keys, DATA TRANSFER DTX (FKY = 31), DATA (FKY = 29) must be assigned.
DISPLAY/AUTO (FKY = 30) is optional.
STEP 3:
ASFC
- For TEC = 13 stations, assign an SFC that at a minimum SFI 11 = 0, DATA LINE
SECURITY.
STEP 4:
ARSC
- Construct a Route Restriction Class that allows access to the desired incoming and outgoing
routes.
STEP 5:
ATNR
- Allow tenant-to-tenant connection for Inter and Intra-tenant connections. Assign Tenant
Restriction Index (TRI) = 1.
STEP 6:
ACFR
- Allow all incoming Call Class Index (CCI) for Transfer Service Feature Index (TSFI)=1.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...