NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 169
Call Transfer - All Calls - D
term
C-11D
Service Conditions (cont’d)
13.
The Camp-on by Station is restricted when the target station is in the three-party connection.
14.
The Camp-on by Station is not available for the target station in LINE LOCKOUT [L-3] condition.
15.
The Camp-on by Station is not available in the following cases:
a.) When the transferred station is dialing the number.
b.) When a call is terminating to the transferred station (the station is ringing).
c.) When the transferred station hears busy tone or reorder tone.
d.) When the transferred station hears special dial tone.
16.
The stations allowed to set the Camp-on by Station (operating station) are D
term
s and analog stations.
17.
When using Camp-on by Station, 1 Dial Hooking cannot be used.
18.
The station to be set the Camp-on by Station (transferred station) is analog, D
term
station and ISDN
terminal.
19.
When the Camp-on by Station is set to the D
term
:
a.) The ANSWER key of the D
term
lights when Warning Tone is received.
b.) At the station to be set the Camp-on by Station, the LCD displays the service set indication
(CAMP) and the trunk kind or the calling number if the Caller ID notification is received.
20.
This service is set by manual operation (see Operating Procedure) because the service becomes effective
when the operating station is released from the connection:
a.) When the operating station is not released within the predetermined time period after receiving
service set tone, the service which has been set will be ineffective. And the operating user hears
busy tone.
b.) When the transferred destination station becomes available before the transferring station is
released from the connection after the service was set (after the operating user hears service set
tone), the trunk incoming call is connected with the destination station after the operating station
(mediate party) replaces the handset.
c.) When the transferred destination station becomes LINE LOCKOUT condition or the destination
becomes make busy before the transferring station is released from the connection after the
service was set (after the operating user hears service set tone), the called station (mediate party)
is recalled even though the station is disconnected.
21.
The following are the conditions when the destination station does not answer within the time period of
No Answer timer:
a.) When the No Answer timer expires, the operating station is called back.
b.) When the No Answer timer expires, call management is decided by the system data (recall to the
operating station or CALL FORWARDING - DON’T ANSWER activation).
22.
The service conditions for Warning Tone are as follows:
a.) The destination station receives the tone used in CALL WAITING service when Camp-on by
Station has been set.
b.) The number of times that the tone is sent is decided on a system basis.
23.
A call can be transferred to a station in the remote node via FCCS link.
24.
The Camp-on by Station can be set to the station in the self-office or the self-node in the FCCS network.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...