Centralized Maintenance - CCIS
C-167
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Assign the following data at the NCN in each FCCS group (FUG)
STEP 1:
AFUGN
- Assign the data related to FUG number
SELF_FUG: Assign the self-FUG number (0-4)
CENTER:
Checkbox is indicated for the self-FUG is the center FUG or not
CON_FUG: 0 = Delete Data
1 - 4, FUG number connected to self-FUG
Assign all the FUGs to be controlled by the Centralized MAT
NCN FPC:
0 = Delete Data
1 - 253, FPC of NCN in the connected FUG
Note:
One FCCS group (FUG) number cannot be allocated to some FUGs in duplicate.
When a number other than “0” is entered to CON_FUG, “0” cannot be entered to the corresponding
NCN_FPC.
A single FUG is to be designated as the Center FUG in one network through FCCS groups and a NEAX2000
IVS
2
.
STEP 2:
AEXFN
- Assign the Point Code data for connecting to each FPC in FUG.
FUG:
Destination FUG number connected to self-FUG (1-4)
FPC:
Fccs network Point Code assigned at CON_FUG (1-253)
PC:
Point Code of node assigned at CON_FUG and connected to the node in remote FUG
via CCIS (PC assigned at ACSC) (1-16367)
Note:
This command is not valid when the self-FUG number has not been allocated by the AFUGN command.
The self-FUG number cannot be entered in FUG parameter.
STEP 3:
Confirm that the data assignment is correct by logging in to each node via the Centralized MAT. Re-
examine the assigned system data if log-in cannot be activated.
For example: The network connection where this service is provided is classified in to three types.
•
To connect FUG and FUG:
Center FUG
FPC 1
PC 1
FUG 1
FPC 3
PC 3
NCN
FPC 2
PC 2
FPC 1
PC 4
FUG 2
FPC 3
PC 6
NCN
FPC 2
PC 5
CCIS
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...