NEAX2400 IPX Feature Programming Manual
Page 462
NDA-24297, Issue 1
L-30
LDN Night Connection - Outside
FCCS Programming
The following command assignments are required to use this feature via FCCS link.
When destination number is programmed by using TYPE = 2 (DC) of ALDNN command
STEP 1:
ASYDL
- System Data 1, Index 640, Bit 0-7. Assign FPC of a node which transmits Day/Night
changeover information.
System Data 1, Index 704-735. Assign FPC of a node which receives the Day/Night changeover
information transmitted from the node assigned by System Data 1, Index 640, Bit 0-7 above.
STEP 2:
ANPDN
- Assign the first digit for Listed Directly Number (LDN) and forwarding destination.
TN:
Tenant Number (1-255)
1st DC:
1st Digit Code (0-9,*,#)
CI:
Connection Status Index (N = Normal/H = Hooking/B = Busy)
NND:
Number of Necessary Digits (max. 6 digits)
BLF:
Busy Lamp Field (0 = Out of Service/1 = In Service)
STEP 3:
ASPAN
- Assign the number of digit of access code for LDN and forwarding destination.
TN:
Tenant Number (1-255)
ACC:
Access Code (max. 6 digits)
CI:
Connection Status Index (N) Normal, (H) Hooking, (B) Busy
SRV:
Kind of Service (Designate “TELN” for LDN, “OGC/OGCA/LCRS” for forwarding
destination.)
NND:
Necessary Digits (1-16)
STEP 4:
ALRTN
- Assign Logical Route Number to Physical Route Number.
LGRT:
Logical Route Number (1-89)
FPC:
Fusion Point Code (1-253)
RT:
External Route Number (1-255)
STEP 5:
ALDNN
- Assign FPC of a node with attendant console which receives the LDN call by dialing
the LDN.
TN:
Tenant Number (1-255)
LDN:
Listed Directory Number (max. 16 digits)
FPC:
Fusion Point Code of the node with attendant console which receives LDN calls
TYPE:
Number Type of Night Mode destination number of LDN (Designate destination number
including access code)
DC:
Assign the Outside Destination Number including access code.
STEP 6:
ACFR
- Allow the Call Forwarding Restriction Class.
TN:
Tenant Number (1-255)
TSFI:
Transfer Service Feature Index (Assign 2 = Direct in Termination (Night only))
CCI:
Call Category Index (Assign 1 = LDN (C.O. Line))
RES:
Restriction Data (Assign 1 = Allowed)
When destination number is programmed by using TYPE = 3 (ADC) of ALDNN command
STEP 1:
ASYDL
- System Data 1, Index 640, Bit 0-7. Assign FPC of a node which transmits Day/Night
changeover information.
System Data 1, Index 704-735. Assign FPC of a node which receive the Day/Night changeover
information transmitted from the node assigned by System Data 1, Index 640, Bit 0-7 above.
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...