NEAX2400 IPX Feature Programming Manual
Page 848
NDA-24297, Issue 1
C-48
Call Forwarding - Intercept - CCIS
Programming (cont’d)
STEP 3:
MBTK
- Assign the Make Idle status to the Announcement Trunk.
Note:
If supervision is required, use the first two circuits of the COT card. Move the switch on the COT card to
PGT.
STEP 4:
ARRC
- If TIE Line or REMOTE ACCESS TO PBX [R-2] connection to the Announcement Service
Trunk is required, allow trunk-to-trunk connection using ARI-D-RES, Direct Connection.
STEP 5:
AAED
- Used to assign Announcement equipment.
DEAD LEVEL
Assign:
TN:
Tenant Number;
EQP:
(Announcement Equipment Number) = 0 (Dead Level). Example: If level 6 is not assigned,
an announcement is heard instead of reorder tone.
RT, TK: Route & Trunk number of the trunk connected to the announcement equipment:
C:
Duration of Connection, 0/1: Disconnection occurs in 30 seconds / the connection is held
until the station releases. See the requirements of the announcement equipment.
R:
Sending RBT, 0/1: Sending RBT/Not sending RBT. Normally assign data “0”.
A:
Answer Signal Sending, 0/1: No answer from Incoming trunk/Answer from Incoming trunk.
Normally assign data “0”. No answer signal is sent to the CO. Therefore calling party will
not be billed for the call.
M:
Multiple Connection 0/1: Single Connection/Multiple Connection. See the requirements of
the announcement equipment.
UNUSED NUMBER
Assign:
TN:
Tenant Number;
EQP:
(Announcement Equipment Number) = 1 (Unused Number).
Example: If ext.-7836 is not in the system, the announcement is heard instead of reorder
tone.
RT, TK: Route & Trunk number of the trunk connected to the announcement equipment:
C:
Duration of Connection, 0/1: Disconnection occurs in 30 seconds/the connection is held
until the station releases. See the requirements of the announcement equipment.
R:
Sending RBT, 0/1: Sending RBT/Not sending RBT. Normally assign data “0”.
A:
Answer Signal Sending, 0/1: No answer from Incoming trunk/Answer from Incoming trunk.
Normally assign data “0”. No answer signal is sent to the CO. Therefore calling party will
not be billed for the call.
M:
Multiple Connection 0/1: Single Connection/Multiple Connection. See the requirements of
the announcement equipment.
STEP 6:
ACFR
- Assignment of Call Forwarding Restriction. Upon determining which types of Call Class
Indexes (CCI) will be answered via CALL FORWARDING-INTERCEPT - CCIS (i.e., CCSA and
DID calls), allow those CCIs a Transfer Service Feature Index of 1, Call Forward-All Calls, Don’t
Answer, Busy.
COT Card
CKT 0
CKT 1
Ring, not used
Voice Tip
Voice
Supervisory Ground
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...