NEAX2400 IPX Feature Programming Manual
Page 866
NDA-24297, Issue 1
C-56
Centralized Day/Night Mode Change - CCIS
C-56
Centralized Day/Night Mode Change - CCIS
General Description
This service feature switches the DAY/NIGHT mode of Satellite Nodes which are linked to the Main Node via
CCIS, in accordance with the DAY/NIGHT mode switching [A-3] at the Main Node.
Operating Procedure
Note:
Node B - Node E are Satellite Nodes.
1.
Press the NIGHT key on the Attendant Console for each Tenant; the NIGHT lamp illuminates. The mode
of Satellite Node for each Tenant changes from Day mode to Night mode.
Note:
To confirm Night Mode, see Night Connection-Fixed - CCIS [N-15].
Service Conditions
1.
A Main Node can control DAY/NIGHT mode changeover for a maximum of 16 remote nodes.
[Node A (Main Node)]
CCIS
CCIS
CCIS
CCIS
ATT
TN=2
TN=3
TN=4
TN=5
[Node B]
[Node C]
[Node D]
[Node E]
TN=1
TN=1
TN=1
TN=1
ATT
TN=2
TN=3
TN=4
TN=5
CCIS
CCIS
CCIS
CCIS
IINDEX19=05
[Node B]
[Node C]
[Node D]
[Node E]
TN=1
TN=1
TN=1
TN=1
INDEX19=04
INDEX19=03
INDEX19=02
:Day Mode
:Night Mode
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...